Refrigerant GWP Tool: Find & Compare Global Warming Potential (Free Guide)
You are choosing a refrigerant for a new system. Or you are retrofitting an old one. You see a number like “GWP 1430” next to R-134a. What does that mean? How does it compare to R-410A or R-32? Why are some refrigerants being phased out?
Global Warming Potential (GWP) is a measure of how much heat a greenhouse gas traps in the atmosphere compared to carbon dioxide (CO2) . It is the single most important number for understanding the environmental impact of a refrigerant. The higher the GWP, the more it contributes to climate change.
Today, I give you a free Refrigerant GWP Tool. This tool lists the GWP and Ozone Depletion Potential (ODP) for over 40 common refrigerants. It helps you compare them at a glance.
What is Global Warming Potential (GWP)? (Simple Explanation)
GWP is a relative measure of how much heat a greenhouse gas traps in the atmosphere over a specific time period, usually 100 years . It is a ratio compared to carbon dioxide (CO2), which has a GWP of 1 .
The higher the GWP, the more a gas contributes to global warming. For instance, R-134a has a GWP of 1,430, meaning it traps 1,430 times more heat than the same amount of CO2 over 100 years .
Why this matters:
- Kigali Amendment: An international agreement to phase down high-GWP hydrofluorocarbons (HFCs) . The goal is to reduce the use of refrigerants with GWP values above 100 .
- EPA Regulations: In the US, the EPA is restricting the use of high-GWP refrigerants in specific applications . For example, new stand-alone refrigeration units must use refrigerants with GWP below 150 starting January 1, 2025 . The EPA has also approved new lower-GWP substitutes for refrigeration and air conditioning .
LIVE Refrigerant GWP Tool
This tool lists the GWP and ODP for common refrigerants. Use it to find the environmental impact of different refrigerants instantly.
Refrigerant Global Warming Potential Calculator
Look up GWP values for any refrigerant. Calculate CO₂ equivalent emissions. Compare refrigerants side by side. See which refrigerants are being phased out — and what to use instead.
Select the refrigerant from your equipment nameplate or service records.
GWP-100 is the standard used in most regulations worldwide.
Loading refrigerant data…
Refrigerant GWP — What It Means and Why It Matters
Global Warming Potential tells you how much a refrigerant heats the planet compared to CO₂. Here’s everything in plain language.
What Is GWP?
Global Warming Potential (GWP) measures how much heat a greenhouse gas traps in the atmosphere over 100 years, compared to CO₂. CO₂ has a GWP of 1. R-410A has a GWP of 2,088 — meaning one kilogram of R-410A leaking into the atmosphere causes the same warming as 2,088 kilograms of CO₂. This is why refrigerant leaks matter for the climate.
CO₂ Equivalent (CO₂e)
CO₂ equivalent is the actual climate impact of a refrigerant leak. The formula is simple: CO₂e = mass leaked × GWP. If 5 kg of R-410A leaks, CO₂e = 5 × 2,088 = 10,440 kg of CO₂ equivalent. That’s the same as driving a car for about 26,000 miles. Minimizing refrigerant leaks is one of the fastest ways to reduce HVAC climate impact.
The Phase-Down Explained
Governments worldwide are phasing down high-GWP refrigerants. The US AIM Act requires an 85% reduction in HFC consumption by 2036. The EU F-Gas Regulation bans new equipment with GWP above 750. The Kigali Amendment to the Montreal Protocol has 197 countries committed to cutting HFCs. This means R-410A — currently the most common AC refrigerant — is being replaced by lower-GWP alternatives.
What Replaces R-410A?
Several refrigerants are positioned to replace R-410A. R-454B (GWP 467) and R-452B (GWP 676) are mildly flammable A2L refrigerants popular in residential systems. R-32 (GWP 675) is already widely used in Asia and Europe. R-466A (GWP 733) is non-flammable and being adopted by some manufacturers. R-290 (propane, GWP 3) is used in smaller systems. None have arrived as a universal single replacement.
ASHRAE Safety Classification
Refrigerants are classified by toxicity (A = non-toxic, B = toxic) and flammability (1 = non-flammable, 2 = mildly flammable, 2L = lower flammability limit, 3 = highly flammable). R-410A is A1 — the safest class. Many low-GWP alternatives like R-32 and R-454B are A2L — mildly flammable, requiring additional installation precautions. R-290 (propane) is A3 — highly flammable, requiring specialized equipment.
Natural Refrigerants
Natural refrigerants like CO₂ (R-744), propane (R-290), isobutane (R-600a), and ammonia (R-717) have extremely low GWPs. CO₂ has a GWP of 1. Propane has a GWP of 3. These are increasingly used in supermarket refrigeration, heat pumps, and domestic appliances. They require careful handling due to pressure (CO₂), flammability (propane), or toxicity (ammonia), but their climate impact is far lower.
📐 GWP Calculation Formulas
CO₂ Equivalent (CO₂e) = Mass of Refrigerant (kg) × GWP
Blend GWP = Σ (Mass Fraction of Component × GWP of Component)
Annual Emissions (kg CO₂e) = Total Charge (kg) × Annual Leak Rate (%) × GWP
GWP Reduction % = (Old GWP − New GWP) ÷ Old GWP × 100GWP-100 is the standard metric — it measures warming impact over 100 years. GWP-20 is sometimes used for short-lived pollutants. GWP values come from IPCC Assessment Reports; the most current values (AR6, 2021) update several refrigerants. For blend GWP, ASHRAE Standard 34 uses a mass-weighted average of component GWPs. This is an approximation — actual atmospheric behavior of blends can differ slightly.
Frequently Asked Questions
🌍 Refrigerant GWP Tool
Find and compare the Global Warming Potential of common refrigerants All Refrigerants High GWP (>1500) Medium GWP (150-1500) Low GWP (<150)
| Refrigerant | Name | GWP (100 yr) | ODP | Safety Group | Type |
|---|---|---|---|---|---|
| R-11 | Trichlorofluoromethane | 4,750 | 1.0 | A1 | CFC |
| R-12 | Dichlorodifluoromethane | 10,900 | 1.0 | A1 | CFC |
| R-22 | Chlorodifluoromethane | 1,810 | 0.05 | A1 | HCFC |
| R-32 | Difluoromethane | 675 | 0 | A2L | HFC |
| R-125 | Pentafluoroethane | 3,500 | 0 | A1 | HFC |
| R-134a | Tetrafluoroethane | 1,430 | 0 | A1 | HFC |
| R-143a | Trifluoroethane | 4,300 | 0 | A1 | HFC |
| R-152a | Difluoroethane | 120 | 0 | A2 | HFC |
| R-290 | Propane | 3-20 | 0 | A3 | HC |
| R-404A | Blend (125/143a/134a) | 3,922 | 0 | A1 | HFC |
| R-407A | Blend (32/125/134a) | 2,110 | 0 | A1 | HFC |
| R-407C | Blend (32/125/134a) | 1,774 | 0 | A1 | HFC |
| R-410A | Blend (32/125) | 1,725 | 0 | A1 | HFC |
| R-448A | Blend | 1,273 | 0 | A1 | HFO/HFC |
| R-449A | Blend | 1,397 | 0 | A1 | HFO/HFC |
| R-454B | Blend (32/1234yf) | 466 | 0 | A2L | HFO/HFC |
| R-455A | Blend | 146 | 0 | A2L | HFO/HFC |
| R-456A | Blend | 150 | 0 | A2L | HFO/HFC |
| R-454C | Blend | 146 | 0 | A2L | HFO/HFC |
| R-471A | Blend | 144 | 0 | A1 | HFO |
| R-515B | Blend | 287 | 0 | A1 | HFO |
| R-600a | Isobutane | 3-20 | 0 | A3 | HC |
| R-717 | Ammonia | 0 | 0 | B2L | Natural |
| R-744 | Carbon Dioxide | 1 | 0 | A1 | Natural |
| R-1234yf | Tetrafluoropropene | 1-4 | 0 | A2L | HFO |
| R-1234ze(E) | Tetrafluoropropene | 1 | 0 | A2L | HFO |
| R-1233zd(E) | Chlorotrifluoropropene | 1 | 0 | A1 | HFO |
Showing 30 refrigerants
📐 GWP values from IPCC AR4/AR5 and ASHRAE Standard 34. ODP = Ozone Depletion Potential. A1 = non-flammable, A2L = mildly flammable, A3 = flammable.
How to Use This GWP Tool
Follow these 3 simple steps.
Step 1: Browse the list of refrigerants in the table above.
Step 2: Use the search bar to find a specific refrigerant by name or number.
Step 3: Use the filter to show only high, medium, or low GWP refrigerants.
The tool shows:
- Refrigerant number and name
- GWP (100-year)
- Ozone Depletion Potential (ODP)
- Safety group (A1, A2L, A3)
- Type (CFC, HCFC, HFC, HFO, HC, Natural)
Understanding the Color Codes
High GWP (>1500): Red. These refrigerants have the highest climate impact. They are being phased down under the Kigali Amendment and EPA regulations.
Medium GWP (150-1500): Yellow. These refrigerants are transitioning out. They will be restricted in new equipment over the next few years.
Low GWP (<150): Green. These are the future. They have low climate impact and are being adopted in new equipment .
GWP by Refrigerant Type
| Type | Examples | GWP Range | Status |
|---|---|---|---|
| CFC | R-11, R-12 | 4,750-10,900 | Phased out (Montreal Protocol) |
| HCFC | R-22 | 1,810 | Being phased out |
| HFC | R-134a, R-410A, R-404A | 120-3,922 | Being phased down |
| HFO | R-1234yf, R-1234ze(E) | 1-4 | Future replacements |
| HFO Blend | R-454B, R-471A, R-455A | 144-466 | Lower-GWP alternatives |
| Natural | R-717 (Ammonia), R-744 (CO2), R-290 (Propane) | 0-20 | Long-term solutions |
EPA SNAP Regulations
The EPA is regulating refrigerants through the Significant New Alternatives Policy (SNAP) program .
Key dates:
- Jan 1, 2025: New stand-alone refrigeration units must use refrigerants with GWP below 150 .
- 2024-2025: SNAP 26 approved new refrigerants for various applications, including R-454C, R-455A, R-457A, and R-516A .
- Ongoing: EPA continues to evaluate additional substitutes under the SNAP program .
Refrigerants approved by SNAP 26 include:
| Refrigerant | GWP | Safety Group |
|---|---|---|
| HFC-32 | 675 | A2L |
| HFO-1234yf | 1-4 | A2L |
| HFO-1234ze(E) | 1 | A2L |
| R-454A | 236 | A2L |
| R-454B | 466 | A2L |
| R-454C | 146 | A2L |
| R-455A | 146 | A2L |
| R-457A | 137 | A2L |
| R-516A | 140 | A2L |
*Source: SNAP 26 *
Frequently Asked Questions (FAQs)
1. What is GWP?
Global Warming Potential is a measure of how much heat a greenhouse gas traps in the atmosphere compared to CO2 .
2. What is a good GWP?
A GWP below 150 is considered good for refrigeration and air conditioning under EPA regulations . Many new systems target GWP below 100 .
3. What is the GWP of R-410A?
1,725 (IPCC AR4/AR5). It is being phased down in new equipment.
4. What is the GWP of R-32?
- It is lower than R-410A and being adopted in new residential AC systems .
5. What is the GWP of R-134a?
1,430. It is being phased down, especially in automotive AC .
6. What refrigerant has zero GWP?
Ammonia (R-717) has zero GWP . Carbon dioxide (R-744) has a GWP of 1 .
7. What is the difference between GWP and ODP?
GWP measures climate impact. ODP measures ozone depletion. Modern refrigerants have zero ODP .
8. How accurate is the GWP data in this tool?
GWP values are from IPCC AR4/AR5 and ASHRAE Standard 34. They may vary by source. Use this tool for comparison, not for regulatory compliance.
Common Mistakes
Mistake #1: Confusing GWP with ODP
GWP is for climate change. ODP is for ozone depletion. They are different. R-22 has both (ODP 0.05, GWP 1,810) .
Mistake #2: Assuming all low-GWP refrigerants are non-flammable
Many low-GWP refrigerants are mildly flammable (A2L) . R-290 (propane) is highly flammable (A3). Follow safety guidelines.
Mistake #3: Ignoring GWP in equipment selection
New equipment may be required to use low-GWP refrigerants. Check EPA SNAP regulations.
Final Thoughts
GWP is the key metric for choosing refrigerants. Low GWP means low climate impact. High GWP means phase-out.
My Refrigerant GWP Tool gives you:
- GWP and ODP for over 40 refrigerants
- Search and filter capabilities
- Color-coded GWP levels
- EPA SNAP regulation context
Bookmark this page. Use it when selecting refrigerants for new systems or retrofits.
The next time you see a refrigerant number, you will know its environmental impact.
Disclaimer: This is an educational tool based on IPCC and ASHRAE data. For regulatory compliance, consult the EPA and your local codes.
External Links (Authority Backlinks):
- Wikipedia – Global warming potential{:target=”_blank” rel=”noopener noreferrer”}
- Wikipedia – Kigali Amendment{:target=”_blank” rel=”noopener noreferrer”}
- Wikipedia – Montreal Protocol{:target=”_blank” rel=”noopener noreferrer”}
- EPA – SNAP Program{:target=”_blank” rel=”noopener noreferrer”}
Read more
- Psychrometric Calculator – Calculate Air Properties (Free Tool)
- Cooling Degree Days Calculator – Understand Your Cooling Needs (Free Tool)
- Heating Degree Days Calculator – (Free Tool)
- AC Replacement Payback Calculator (Free Tool)
- HVAC Energy Savings Calculator – Estimate Annual Savings (Free Tool)
- Disconnect Size Calculator – Motor & AC Safety Switch (Free Tool)
- Motor FLA Calculator – Full Load Amps Tool (Free)
- VFD Speed Calculator – Motor RPM from Frequency & Poles (Free Tool)
- Capacitor Calculator HVAC – Size Start & Run Capacitors (Free Tool)
- Breaker Size for AC Unit – MCA & MOCP Calculator (Free Tool)
- Ton to Amp Calculator – Convert AC Tons to Amps (Free Tool)
- AC Unit Amperage Calculator – RLA & LRA (Free Tool)
- Celsius to Fahrenheit Converter – Instant Temperature Tool (Free)
- Cubic Meters to Pounds Converter – Volume to Weight (Free Tool)
- Cooling Load Calculator – Find Your AC Size (Free Tool)
- Superheat Calculator – HVAC Refrigerant Superheat (Free Tool)
- kWh Cost Calculator – Estimate Electricity Costs (Free Tool)
- Chilled Water Flow Rate Calculator – GPM Tool (Free)
- Boiler BTU Calculator – Size Your Heating System (Free Tool)
- Expansion Tank Size Calculator – Hydronic System Sizing (Free Tool)
- Water Pipe Sizing Calculator – Find the Right Diameter (Free Tool)
- Heat Loss Calculator – Size Your Heating System (Free Tool)
- U-Value Calculator – Calculate Wall & Window Heat Loss (Free Tool)